Switch Gear
VS 12
This page is best viewed with JavaScript enabled.
Technical Details

Breaker type VS12 is a 3 phase outdoor, porcelain clad vaccum circuit breaker. It is designed to have provision for double trip and series trip coil. The standard breaker is provided with 8NO+8NC auxiliary contacts (additional contacts can e provided as required).


The breaker is routine tested for soundness of execution by applying 200 open/trip operation which is over and above the IS 13118 specifications. The VCB is rated for a maximum current, voltage and breaking capacity of 1600A, 11kV and 26.3kA respectively. Easy maintenance and high reliability adds advantage to this VCB.

Features
  • A sturdy Compact , maintenance free Mechanism design suitable for 100000 (one hundred thousand) Operations.
  • Reciprocating Bar operates all 3 phase drives instead of the usual Rotating Shaft and independent support under all the 3 Interrupters eliminates Pole discrepancy.
Specification
Type reference VS12
Applicable standard IEC 62271-100/IS 13118
Rated voltage 11kV
Rated normal current 1600A
Operating Sequence O-0.3sec-CO-3min-CO
Rated power Freq. withstand 28kV
Rated impulse withstand voltage 75kVp
Rated short circuit breaking current 26.3kA
Rated closing/tripping voltage 24/30/48/110/220V-DC
First pole to clear factor 1.5
Rated duration of short circuit 3sec
Dimension of OLTC VIEWCLOSE
VS 36
This page is best viewed with JavaScript enabled.
Technical Details

Breaker type VS36 is an outdoor, 33kV, porcelain clad vacuum circuit breaker. The standard breaker is provided with 8NO+8NC auxiliary contacts(additional contacts can be provided as required). For the manual close/open breaker operations Push buttons are provided. The Pole units comprising vacuum interrupter and other insulating rods are filled with Nitrogen at 0.5 kg, pressure to prevent surface tracking. Easy installation and high reliability adds advantage to this breaker. The breakers are designed having provisions for double trip coil and series trip coil arrangement.


Features
  • A Sturdy Compact, maintenance free Mechanism design suitable for 100000 (one hundred thousand) Operations.. Reciprocating Bar operates all 3 phase drives instead of the usual Rotating Shaft and independent support under all the 3 Interrupters eliminates Pole discrepancy
  • Visible Snatch Gap to determine Contact Erosion
  • Sleek and Compact look
  • Large Creepage over the Operating Rod
  • Easy Accessibility for servicing
  • Silent Spring Charging Operation
Specification
Type reference VS36
Applicable standard IEC 62271 – 100/IS 13118
Rated voltage 33kV
Rated normal current 2000A
Operating Sequence O-0.3sec –CO -3min – CO
Rated power Freq. withstand(kV) 70kV
Rated short circuit marking current 66.5kA
Rated short circuit breaking current 26.3kA
Rated closing/tripping voltage 24/30/48/110/220V-DC
First pole to clear factor 1.5
Rated duration of short circuit 3sec
Dimension of OLTC VIEWCLOSE
KS 12
This page is best viewed with JavaScript enabled.
Technical Details

Breaker type KS 12 is a 3 Phase,12 Kv Outdoor Kiosk, horizontal drawout fixed type, Outdoor Vacuum Circuit Breaker. The breaker is fully type tested and confirms to IEC 62271-100/200. The breaker has both mechanical and Electrical close/Open Facilities. The breaker is rated for a maximum current, Voltage and breaking capacity of 630 A, 12 Kv, AND 16 ka respectively.


Features
  • A sturdy Compact, maintenance free mechanism suitable for 10000 (One Hundred Thousand) operations.
  • Compact Design (720W x 2300H x1440D)
  • Reciprocating Bar operates all 3 Phase drives
  • Independent Support under all the 3 interrupters ensures simultaneity of Pole operations
  • Trip free silent spring charging operation
  • Suitable for hot/humid/tropical atmosphere(IP55 degree of Protection
  • Draw out breakers on roller base for easy maintenance
Specification
Type reference KS 12
Applicable standard IEC 62271-100/IS 13118
Rated voltage 11kV
1 min A.C withstand test level 35kV
Impulse withstand 75kVp
Current ratings 630A
Operating Sequence O-0.3sec-CO-3min-CO
Rated Short Circuit Withstand Current 16kA for 3 Sec
Rated Peak Withstand Current 40kA Peak
Rated Short Circuit Breaking Current 16kA R.M.S
Rated Short Circuit Making Current 40kA Peak
Degree of Protection IP55
Dimension of OLTC VIEWCLOSE
Outline Diagram
Load Break Switch
This page is best viewed with JavaScript enabled.
Features
  • With the provision of HRC fuses and Vacuum Interrupter we could achieve selective fault protection according to the fault severity.
  • Ideally suitable up to 1600 kVA
  • Since Arc quenching medium is air, no need to provide additional insulation. Hence it is most Economical
  • Designed to operate up to 10000 operations with minimal Mechanical and Electrical components
  • It is more reliable since no need for additional cooling medium
Specification
Rated Voltage 11 kV
Maximum System Voltage 12 kV
Rated Current 630 A
Rated Short time with stand Current 20 kA
Rated peak with stand Current 50 KA
Rated Short Circuit making Current 50 kA
Rated breaking Current of Load with Power 630 A
Rated close ring breaking Current 630 A
Rated break Cable Charging Current 10 A
Rated idle load Transformer breaking 1600 kVA
Insulation level(rms) 35 kV
Mechanical lifetime(C-O cycle)
a)Vacuum load Switch 10000 Nos
b)Isolator and Earth Switch ≥ 2000 Nos.
Three phase simultaneous closing ≥ 5 ms
Outline Diagram